Energy efficient Server Cabinet for Data Center

The elements that allows organizing the physical separation of air flow in the first place is the server cabinet. Impact on the quality of the cabinet air is often underestimated by many. Consider the problem solved by the cabinet:

The main problems that are solved with the help of server racks:

Placing server equipment;
Ensuring continuous cooling of installed equipment;
Organization power servers;
Organization of SCS;
Physical security of the installed equipment;

Each cabinet used in data centers, and performs tasks described above must also meet the following requirements:

Server rack, developed by Uptime Technology has a number of advantages compared to other cabinet manufacturers.

Some features of the server cabinet. The cabinet is designed to meet the requirements of heat exchange:

Cabinet is detachable. The cabinet is supplied unassembled. Cabinet assembly can be carried out independently for 30 minutes. For assembly use only one installation tool supplied with the cabinet.

The volume of space occupied in the transport container is 2 times lower than the standard cabinet with a welded frame. This feature provides the following benefits:

Reduce the cost of transportation. For example, compare two cases of the same size in mm.: 600х1200х2200. Suppose we decided to buy 20 cabinets. For the transport of nondemountable cabinets of this size (without packaging) we need a truck with a capacity of about 32 cubic meters body. For transportation of the same amount of unassembled cabinets we need 16 cubic meters in volume, which corresponds to the possibility of a more modest transport. The difference in the cost of delivery will be the amount of about 0,3 USD every kilometer of the way, but not less than 30 USD - the difference in the cost of cars shift work.

Most relevant example is when you get one or two racks. Transportation dismountable racks available in a minivan, often already in the fleet. For transportation of a nonseparable cabinet you will need a minimum of a truck, as most manufacturers prohibit the transportation in the "lying down", and height of the rack limits the applicability of light commercial vehicles. In this case, the cost difference can make a several tens USD for each cabinet.

Reducing storage costs. It is not always possible to install all the cabinets at the same time, so it is often a question of storage equipment. No matter where you stored on our own warehouse, or rented - the need for the amount of equipment stored in two times less than in the case of nonseparable cabinet.

Technical data:

High, U

42

48

V х W х D, mm

2033 х 600 х 1200

2300 х 600 х 1200

Usable depth, mm

1000

1000

Weight, kg

138

159

Distributed load, kg

1000

1150

Heat sink (direct fow), KW           

up to 50*

up to 56*

Surface finish

Powder-Polymer enamel

Color, RAL

Standart – 5020 (any on request)

Material

Steel

Numbers of doors

2

Way to open the door

Double-sided

Type of doors

Breathable, perforated

Breathability of perforation

82,7%

Protection class

IP30

 

 

 

Completeness of delivery

Bottom part – 1 pcs.;

Top part – 1 pcs.;

Front frame with door – 1 pcs.;

Back frame with door – 1 pcs.;

Side covers – 2 pcs.;

Plugs - set at 20 U;

Assembly instructions, tools, fasteners, packaging.

* - Note: provided by cold air with the maximum temperature to 24 ° C and the evacuation of hot air at a temperature of not less than 36 ° C.

Ask a question or make a request to the server cabinet here.